W5-Ethernet-Manual.doc
Version 2.0-01
Watson 5 Ethernet
Operating Manual
Revision: 2006-04-27 7-21
On the tabletop:
NTU_FMM_REMOTE> ALARM
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Alarm Status
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LOOP1:off ACO:off LKINT:on
LOOP2:off ALB:off
LOSW-A:off BER-A:off SEG-A:off BERT:off
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Alarms (plugin):
BER
High bit error rate on DSL (CRC6 – faults)
LOSW
DSL loss of synchronization word
LKINT
Ethernet link integrity
LOOP
Test loop active
Parameter:
T
Turns alarm trace on / off. When ALARM T is active then each change in the
alarm status will be shown on the screen with a time stamp counted in
min:sec:millisec from the last system reset.
To deactivate alarm trace enter ALARM T a second time or leave the FMM
menu.
Alarms:
ACO
Alarm cutoff
ALB
Analog loopback (Watson 5 Ethernet tabletop only)
BER
BER-A
BER-B
SDSL block-error-rate according G.826 ≥ 30%
LKINT
Ethernet link integrity
LOOP
LOOP1
LOOP2
Test loop active
LOSW
LOSW-A
LOSW-B
DSL loss of synchronization word
Comments to this Manuals