Page view 40
W5-Ethernet-Manual.doc
Version 2.0-01
Watson 5 Ethernet
Operating Manual
Revision: 2006-04-27 3-25
tor access must be enabled by entering the password before any Monitor commands can be en-
tered.
Once the password is entered all Monitor commands are available. The password has to be re-
entered
! after each LOGOFF
! after 5 minutes of inactivity
! after a restart of the modem
Passwords can be changed with the CHANGE PASSWORD command. To disable password pro-
tection use the CLEAR PASSWORD command.
Password protection is only applied to access from the local RS-232 interface. Monitor access
through the DSL EOC is never protected by the password. If a password has been lost then it can
be reset through the DSL EOC with the CLEAR PASSWORD and SET PASSWORD com-
mands.
Of course this is only possible if the modem who's password has been lost is configured as DSL
slave. If it is configured as DSL master then no remote access through the DSL EOC is possible. In
this situation the modem can be configured as DSL slave with the DSLSLAVE command which
can be entered at the prompt for the password. After DSLSLAVE the modem will be reconfigured
as DSL slave and the password can be reset from the DSL master as described above.