Schmid Watson Specifications Page 60

  • Download
  • Add to my manuals
  • Print
  • Page
    / 103
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 59
Watson 5 Ethernet
Operating Manual
W5-Ethernet-Manual.doc
Version 2.0-01
7-6 Revision: 2006-04-27
RESTART ON | OFF
Set Autorestart ON / OFF.
7.1.4 Ethernet Configuration (Plugin)
FDX Ethernet-Port mode
Sets duplex mode and speed of an Ethernet port (ETH1 .. ETH4).
Possible values for mode:
AUTO Autonegotiation of parameters
10H 10 MBit/s, half duplex
10F 10 MBit/s, full duplex
100H 100 MBit/s, half duplex
100F 100 MBit/s, full duplex
FLOW Ethernet-Port AUTO | ON | OFF
Ethernet flow control:
AUTO Auto negotiation
ON flow control enabled
OFF flow control disabled
Flow control is implemented with PAUSE frames in full duplex mode and with backpressure (forced
collisions) in half duplex mode.
Note
It is not possible to auto-negotiate flow control without auto-negotiating speed and duplex modes.
Setting FDX to a value different from AUTO and then setting FLOW to AUTO results in disabling flow
control, i. e. has the same effect as FLOW OFF.
7.1.5 Ethernet Configuration (Tabletop)
BITRATE n
Defines the bandwidth of bridged data between Ethernet and DSL interface (n = number of 64
kbit/s timeslots, 1 .. 72).
Must be aligned to the linerate on the DSL link.
When the bitrate configured with the BITRATE command exceeds the available DSL linerate an
appropriate warning is displayed.
Cf. chapter 3.2
CONFIG
Displays the current configuration of DSL and Ethernet ports. Cf. 7.1.3.
CLOCKMODE 0 | 1
Determines the clock source used to transfer data from MAC layer of the Ethernet interface to the
DSL interface.
0 internal clock. Recommended configuration for modems operating as DSL masters
1 remote clock. Recommended configuration for modems operating as DSL slaves.
Page view 59
1 2 ... 55 56 57 58 59 60 61 62 63 64 65 ... 102 103

Comments to this Manuals

No comments