7.5.1 ADDRESS Command
The ADDRESS command allows the user to assign an address number in the range between 1
127 to the current DSL interface of a Minirack LTU.
LTU_01_CM> ADDRESS 04
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Configuration Id : 2 Mbit/s G.703
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
2 Mbit/s
Framing : ITU-T G.704
CRC4 : On
E-Bit Insertion : On
AIS Generation : On
AIS Detection : On
External Clock : Disabled
Data Rate : 31 x 64 = 01984 kbit/s
SHDSL
Master/Slave : Master
Autorestart : Enabled
Power Backoff : Disabled
Payload Rate : 02048 kbit/s
Operating Mode : 1 Pair
Line Rate : 02056 kbit/s
Remote Powering : On
Regenerators : --
TMN
Address : 04
V.11 wires : 04
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
LTU_01_CM>
Note:
For a Dual LTU Minirack it is possible to assign a higher interface address number to DSL system
A than to DSL system B.
For Plug-in LTUs the lowest interface number is always assigned to DSL system A and the pins
with appropriate designation on the DSL connector of type RJ-45.
Note:
Carefully note already used interface address numbers. No automatic protection against multiple
LTUs assigned to the same interface address number can be applied in a set-up with several
Minirack LTUs.
Two interfaces with same address number on the TMN bus will cause malfunction and the units
will not be accessible by the TMN application SW.
Limitation:
Both DSL systems of a Dual LTU can be addressed freely. But possible addresses are limited to
the address ranges 01 - 12 and 33 – 44 by the Simple Network Management Protocol (SNMP)