7.4 Monitor Commands for the nx64 kbit/s Interface
This section deals only with nx64 kbit/s specific monitor commands.
7.4.1 Fault and Maintenance Management FMM
7.4.1.1 ALARM Command
NTU_FMM> ALARM
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Local Alarm Status
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
DTR-S:off LOOP1:off ACO:off
LOC-S:off LOOP2:off ALB:off
LOSW-A:off BER-A:off SEG-A:off BERT:off
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NTU_FMM>
These alarms are related to the nx64 kbit/s interface:
DTR-S: Status of DTR (Data Terminal Ready) Handshake Signal in V.35/V.36 mode. For X.21
mode, the Control-signal (C) is represented by the DTR-alarm.
DTR Signal is detected as ‘ON’ (Status: off)
DTR Signal is detected as ‘OFF’ (Status: on)
LOC-S: Loss Of Clock (When Local Clock mode is selected). LOC is also active when the
incoming clock bit rate is not equal to the programmed bit rate (n).
Clock master present with correct bit rate (Status: off)
Clock master not present and/or bit rate mismatch (Status: on)
When both an nx64 kbit/s and an E1 interface are equipped, the alarm display shows first the
E1/PRA alarms and then the nx64 kbit/s alarms.