Schmid Watson Installation Guide Page 79

  • Download
  • Add to my manuals
  • Print
  • Page
    / 129
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 78
LTU/NTU SZ-DOC-W5-1.pd
f
Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 70
7.4.2 Configuration Management CM
User Interface in V.35 or V.36 mode
NTU_CM> H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CONFIG Display local configuration
BITRATE [0..72] Set bit rate of nx64 Port
CLOCKMODE [0,2,3] Select clock source:
0=nx64 Port, 2=internal, 3=remote
CLOCKDIR [0,1] Set clock direction of nx64 Port:
0=codir, 1=contradir
V54LOOPS [ON,OFF] Set V.54 loop control on/off
HANDSHAKE [ON,OFF] Set RTS/CTS (C/I) handshake on/off
UIF type Select user interface type
MASTER [ON,OFF] Set SHDSL master mode / slave mode
RESTART [ON,OFF] Set autorestart on/off
BACKOFF [ON,OFF] Set power backoff on/off
DEFAULT [0..2] Set default configuration
M(AIN) Return to main menu
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NTU_CM>
User interface in X.21 mode
NTU_CM> H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CONFIG Display local configuration
BITRATE [0..72] Set bit rate of nx64 Port
CLOCKMODE [0,2,3] Select clock source:
0=nx64 Port, 2=internal, 3=remote
CLOCKPOL [0,1] Set clock polarity of nx64 Port:
0=normal, 1=inverted
BYTETIMING [ON,OFF] Set byte timing on/off
HANDSHAKE [ON,OFF] Set RTS/CTS (C/I) handshake on/off
UIF type Select user interface type
MASTER [ON,OFF] Set SHDSL master mode / slave mode
RESTART [ON,OFF] Set autorestart on/off
BACKOFF [ON,OFF] Set power backoff on/off
DEFAULT [0..2] Set default configuration
M(AIN) Return to main menu
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
NTU_CM>
When both an nx64 kbit/s and an E1 interface are equipped, also E1 or PRA specific
configuration commands will be listed in the menu.
Page view 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 128 129

Comments to this Manuals

No comments