LTU/NTU SZ-DOC-W5-1.pd
f
Operating Manual
V
ersion: 1.5
Revision: 2002-09-10 32
4.2.2 E1 Interface
Slave
CRC4 CRC6
TX
RX
E1
Test
Gen.
CRC4/E-bit
G.826
Evaluation
Gen.
Test
CRC6
DSL
Master
CRC6 CRC4
Test
Gen.
CRC4/E-bit
G.826
Evaluation
Gen.
Test
CRC6
TX
RX
E1
Test
Gen.
G.826
Evaluation
Gen.
Test
CRC4_T CRC6
Test
Gen.
Evaluation
CRC6
DSL
Channels A & B
E1
E1
G.826
TX
TX
RX
RX
CRC6
CRC6CRC4/E-Bit
Slave Master
Figure 4-1: E1 G.826 Performance Evaluation
On the E1 side, four CRC4 check bits are generated per sub-multiframe (SMF) and compared
with the corresponding CRC4 bits in the following SMF. If they do not match, the CRC4 error
counter is incremented. The opposite station is informed of detected CRC4 errors by setting E-
bits in the transmitted frames. At the same time, the E-Bits from the opposite station are counted
and can be used for performance monitoring.
For the E1 interface, calculations according to G.826 are only possible in framed mode with
CRC4 option enabled. In framed mode with CRC4 option disabled only FAS-errors are detected.