Schmid Watson Specifications Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 130
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
Watson-TDM-Manual-W.doc
Version 2.0-01
Watson TDM
Operating Manual
Revision: 2008-02-07 8-19
Working Line, Protection Line
Line
System address
Switchovers
Number of switchovers
Last Switchover
Time of last switchover
Switchover Sec-
onds
Cumulative protection switching duration time in sec-
onds, i. e. the cumulative number of seconds that ser-
vice was carried on the protection line.
Note:
The counters start counting as soon as the APS group is activated (GROUPn
ON). They are reset with the RESETAPS command or by deactivating the group
(GROUPn OFF).
APS command issues a command to the APS group:
Command
Result
2
clear: clears any active command
3
Lockout of protection: Prevents the working line from
switching to the protection line
4
Forced switch work to protect: switches from the work-
ing line to the protection line regardless of the current
state of the protection line
5
Forced switch protect to work: switches from the protec-
tion line to the working line regardless of the current
state of the working line
6
Manual switch work to protect: switches from the work-
ing line to the protection line unless there is a failure on
the protection line
7
Manual switch protect to work: switches from the pro-
tection line to the working line unless there is a failure
on the working line
8
Exercise: accepts and acknowledges a switchover
command without actually executing the switchover
RESETAPS
Resets the APS counters.