Watson-TDM-Manual-W.doc
Version 2.0-01
Watson TDM
Operating Manual
Revision: 2008-02-07 5-3
Note:
If a remotely powered tabletop modem consumes more power than can be fed
over the DSL link then it will not start up properly. This can lead to the loss of a
remote modem through misconfiguration, e.g. by enabling the nx64 interface on
a multiservice modem which is operating at the power limit with the nx64 inter-
face switched off. With such reconfigurations the power consumption of the mo-
dem increases and it will not work properly anymore, making it impossible to get
back to a working configuration under remote control. In such cases manual in-
tervention at the site of the remote modem is required to reconfigure the unit with
a local terminal.
The reach attainable with remote powering depends on the power consumption
of the modem and on the loop resistance (wire diameter and cable length and re-
sistance of the feeding/protection circuitry in the plug-in).
5.3.2 Remote powering of Tabletops
The tabletops have a backplane switch to select local or remote powering. In the
default switch position "REM" the tabletop modem is powered via the DSL line
and will start operation immediately after connection of the DSL line. In position
"LOC", the tabletop modem is powered locally and needs to be connected to a
power supply to operate.
5.3.3 Powering Status Display
The current powering status of a tabletop modem is available in the STATUS dis-
play of the monitor (Unit Power Source UPS):
UPS = 01 for local powering
UPS = 02 for remote powering
5.3.4 Power Failure Alarm
The power supply bit fbit3 of the DSL frame is used to indicate the status of the
local power supply in the tabletop modem. The power status bit is set to ONE if
power is normal and to ZERO if the power has failed. In case of power loss at the
remote modem there is enough power left to communicate three "Power Loss"
messages towards the LTU. In case of a failure of the tabletop modem power
supply, both LEDs will be extinguished.