8.5 Security and Remote Management SM
LTU_01_SM> H
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
CONNECT adr (CON) Connect remote terminal (adr=[2..10])
2=NTU remote, 3=REG 1, 4=REG 2, etc.
DISCONNECT (DIS) Disconnect remote terminal(s)
alternatively press <Esc>
RHM Read HM-Code
RCHM Read CHM-Code
RFW Read FW-Code
MAIN (M) Return to main menu
8.5.1 Connection control
CONNECT
The CONNECT n command sets a connection to a remote unit for configuration
purposes. A remote unit is either a regenerator or the NTU. Remote units are ad-
dressed as per TS 101 524, see Table 8-5. If no address is entered the CONNECT
command will connect to the NTU.
Device Unit Address
LTU, DSL Master 1
NTU, DSL Slave 2
Regenerator 3-10
Table 8-5: SHDSL EOC addressing
DISCONNECT
The DISCONNECT command breaks the connection to the remote unit. If no re-
mote terminal is currently connected, the DISCONNECT command lists all remote
units currently available. Instead of typing DISCONNECT, the ESC key can be
used to return to the local terminal in a more convenient way.
Note:
The CONNECT and DISCONNECT commands are available from all sub-menus, but
are not displayed in the respective help screens.
8.5.2 Inventory
RCHM
The RCHM command reads out the hardware and firmware identification code of
the modem (CHM Code).
RFW
The RFW command displays the version of the currently installed firmware.
RHM
The RHM command reads out the serial number (HM code) from the modem.