Schmid Watson Specifications Page 51

  • Download
  • Add to my manuals
  • Print
  • Page
    / 130
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 50
Watson-TDM-Manual-W.doc
Version 2.0-01
Watson TDM
Operating Manual
Revision: 2008-02-07 3-29
E1 Interface
Slave
CRC4
CRC6
TX
RX
E1
Gen
CRC6
DSL
Master
CRC6 CRC4
Test
Gen
.
CRC4/E-bit
Test
CRC6
TX
RX
E1
Test
Evaluation
G.826
Evaluation
G.826
Gen
.
Test
CRC4/
E-bit
Gen
.
Figure 3-20: E1 G.826 Performance Evaluation
On the E1 side, four CRC4 check bits are generated per sub-multiframe (SMF)
and compared with the corresponding CRC4 bits in the following SMF. If they do
not match, the CRC4 error counter is incremented. The opposite station is in-
formed of detected CRC4 errors by setting E-bits in the transmitted frames. At the
same time, the E-bits from the opposite station are counted and can be used for
performance monitoring.
For the E1 interface, calculations according to G.826 are only possible in framed
mode with CRC4 option enabled. In framed mode with CRC4 option disabled
only FAS-errors are detected.
ISDN PRA Interface
CRC4_T
CRC4_V3
TX
RX
E1
Gen
.
CRC6
DSL
Master
CRC6
Test
Gen
.
CRC6
TX
RX
E1
Test
Evaluation
G.826
Evaluation
G.826
Gen
.
Test
CRC4/
E-bit
Test
Gen
.
CRC4/E-bit
CRC6
Slave
Figure 3-21: PRA G.826 Performance Evaluation
When the PRA interface works with CRC4 processing or monitoring (options 2
and 4) four CRC4 check bits are generated per sub-multiframe (SMF) received
from the ET and the NT2/TE and are compared with the corresponding CRC4
bits in the following SMF. If they do not match, the corresponding CRC4 error
counter is incremented. At the same time, the E-bits from the ET and the NT2/TE
are counted and can be used for performance monitoring.
Page view 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 129 130

Comments to this Manuals

No comments