7-39
7.5.3 Password
CHANGE PASSWORD
The CHANGE PASSWORD command is used to change a password. The old
password has to be known to change it. The new password must be entered
twice to confirm it.
NTU_SM> CHANGE PASSWORD
Old password: ******
New password: ******
Confirm new password: ******
52:11:40 new password set
CLEAR PASSWORD
The CLEAR PASSWORD command clears the currently set password and disables
password protection. This is the factory default setting.
NTU_SM> CLEAR PASSWORD
Old password: ******
Password cleared and Monitor protection disabled
DSLSLAVE
The DSLSLAVE command is the only command allowed while password protec-
tion is active. The DSLSLAVE command is used to configure a master tabletop as
a DSL slave to allow a remote terminal access in case the password of a master
tabletop has to be changed or cleared.
Monitor Password Protection
Enter password: ******** (typed DSLSLAVE)
Device is now DSL slave
Note:
Through the remote terminal, i.e. through the DSL EOC the password commands
are available without password protection. If a modem has been password pro-
tected and the password has been lost then it can be cleared again from modem
configured as DSL master. If the modem who's password has been lost is confi-
gured as DSL master it can be set to DSL slave with the DSLSLAVE command
that is available even while password protection is active.
LOGOFF
LOGOFF activates the password protected mode. The previously set password
has to be entered before any new Monitor commands can be issued via the local
terminal.
SET PASSWORD
The SET PASSWORD command allows definition of a password on the tabletop.
Once a password is set the modem will go into a protected mode either after the
command LOGOFF is issued, after a timeout of 5 minutes or after a restart.