Schmid Watson Specifications Page 115

  • Download
  • Add to my manuals
  • Print
  • Page
    / 134
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 114
Watson-Ethernet-Manual.doc
Version 3.3-01
Watson Ethernet
Operating Manual
Revision: 2010-01-20
8-11
Implemented notifications:
loop1Alarm
initAlarm
acoAlarm
locAlarm
remotePowerFailureAlarm
resetAlarm
linkIntAlarm
confEr03Alarm
confEr04Alarm
confEr05Alarm
bertAlarm
loswAAlarm
loswBAlarm
berAAlarm
berABlarm
8.2.16 Schmid MIB
The Schmid MIB contains vendor-specific hardware identifiers (called the model
codes) for Schmid DSL modems. The model code can be read as sysObjectID
in the system group of mib-2.
Implemented data structures:
schmidGeneralWatsonModelCodes group
8.2.17 Watson MIB
The Watson MIB contains vendor-specific data structures for Watson modems.
Implemented data structures:
watsonSpecificCardTable to configure
- Card Reset
- CoS Scheduling Policy
- Cardmode
- Bridgemode
watsonSpecificIfConfTable to configure
- interface-specific CoS features (Rate limiting, priority source)
- doubletagging
- MAC Defect Signaling
Page view 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 133 134

Comments to this Manuals

No comments